Skip to Main content
Skip to Footer
Login
×
English
×
Contact Us
Clear
Search
Related content
Products
Show all results
Wishlist
Cart
Cables
Coaxial cables
Flexible
Low-loss, 50 Ohm, 6 GHz, 85°C, ø3.15 mm, LSFH jacket
Low-loss, 50 Ohm, 6 GHz, 85°C, ø3.15 mm, LSFH jacket
Product number 22512310
Identifier S_02162_B
Variation: -
Product code
S_02162_B
Cable family
S: Low loss RF cables with foam PE dielectrics
Available as assembly only
No
Cable group
S9
Enter your total quantity (in meters)
m
General Information
Key features
Alternative to standard SPUMA cables
Low loss
Low smoke
Flame retardant
Enter your total quantity (in meters)
m
Specifications
Construction
Component
Material
Detail
Diameter
Cable jacket print
Centre conductor
Copper
Strand-07
0.8 mm - 0.05 mm
Dielectric
SPE (Foamed Polyethylene)
2.1 mm
Outer conductor
Aluminum / PES
longitudinal Foil, 100%
2.15 mm
Outer conductor
Copper, Tin plated
Braid, 75%
2.65 mm
Jacket
LSFH (modified polyethylene)
RAL 9005 - bk
3.15 mm +/- 0.05 mm
HUBER+SUHNER S 02162 B 50 Ohm (production order number)
Electrical data
Impedance
50 Ω +/-2Ω
Operating frequency
≤ 6
GHz
Capacitance
82
pF/m
Velocity of signal propagation
81
%
Signal delay
4.08
ns/m
Screening effectiveness
80 dB at frequency 0.001 GHz ... 6GHz
Insulation resistance
100000000
MΩ*m
Inner conductor resistance
41.8
Ω/km
Operating Voltage (at sea level)
≤ 0.25
kVrms
Test voltage (50 Hz/1 min)
≤ 0.5
kVrms
Mechanical data
Weight
approx. 25
g/m
Static bending radius
≥ 16
mm
Repeated bending radius
30 mm (bendings, up to 500)
Dynamic bending radius
< 50
mm
Load test
IEC 794-1-E3
Tensile stress test
VW TL 821 33
Abrasion test
MIL-T-81490 - §4.7.19 - prod. II - modified
Environmental data
Operation temperature
-40 °C ... 85 °C
Installation temperature
-20 °C ... 60 °C
Flame propagation standard
IEC 60332-1
Fire characteristics
free of halogenes, acc. standard IEC 60754
Ageing test
VW TL 821 33
Thermal stress test
IEC 61196-1 § 10.9
Please enable JavaScript to continue using this application.